Reckoner for all Coal Conversions - Knowledge is Power

1 btu/lb = 0.002326 mj/kg 1 kcal/kg 0.0041868 mj/kg 1 metric ton (tonne) 1.10231 short tons. From GAR to NAR : The difference between net and gross as received (NAR v/s GAR) specific energy values is the latent heat of the water vapour which lowers the effective calorific value in the boiler.

Get Price >>

Camelot Coal Company - Coal Sales - Steam Metallurgical

Our supplier steam coal products range from 8,400 BTU/lb sub-bituminous PRB coals to 13,000+ BTU/lb NAPP coals, having sulfur content ranging from ultra compliance (1.0# SO2/mm BTU) to 2+ sulfur. METALLURGICAL COAL Metallurgical Coal, also known as coking coal, supplies the heat and carbon used in the steel mill process to make steel products.

Get Price >>

Coal Conversion Facts - drummondco.com

WORLD COAL INSTITUTE [email protected] August 2007 Calorific Values (CV) Units: kcal/kg – kilocalories per kilogram MJ/kg* – Megajoules per kilogram Btu/lb – British thermal units per pound * 1 MJ/kg = 1 Gigajoule/tonne (GJ/t) Gross & Net Calorific Values Gross CVor 'higher heating value' (HHV) is the CV under ...

Get Price >>

Steam Coal vs. Pet Coke

Steam Coal vs. Pet Coke Updates and Usage Comparison Updates: 2009 steam coal production, consumption and trade (from the 2010 IEA Coal Information book for 2009 Coal Data) Usage: Power Plant's Decision on Buying Pet Coke to Blend with Coal

Get Price >>

Bituminous coal | coal classification | Britannica.com

Jul 17, 2019· Bituminous coal, the most abundant form of coal, intermediate in rank between subbituminous coal and anthracite according to the coal classification used in the United States and Canada. In Britain bituminous coal is commonly called "steam coal," and in Germany the term Steinkohle ("rock coal") is

Get Price >>

GLOBAL INDENTORS STEAM COAL, THERMAL COAL, ANTHRACITE ...

Coal power plants throughout the nation use coal to generate electricity. Due to steam coal's natural combustible nature, power plants use combustion. We exclusively trade thermal coal of Indonesian origin and offer main calorific values – GAR 4200 kcal/kg, NAR 4700 kcal/kg and NAR 5500 kcal/kg.

Get Price >>

Convert kcal to Btu [thermochemical] - Conversion of ...

››More information from the unit converter. How many kcal in 1 Btu [thermochemical]? The answer is 0.25188740503607. We assume you are converting between kilocalorie [15 °C] and Btu [thermochemical]. You can view more details on each measurement unit:

Get Price >>

BTU to tons of refrigeration (RT) conversion calculator

Tons to BTU/hr conversion calculator How to convert BTU/hr to tons. One refrigeration ton is equal to 12000 BTUs per hour: 1 RT = 12000 BTU/hr. One BTU per hour is equal to 8.33333×10-5 refrigeration ton: 1 BTU/hr = 8.33333×10-5 RT . So the power P in refrigeration tons (RT) is equal to the power P in BTUs per hour (BTU/hr) divided by 12000:

Get Price >>

NAPP coal near-term pricing remains strong: sources | S&P ...

Platts on Friday assessed NAPP coal (13,000 Btu/lb, <3.0 lbs SO2/MMBtu) at $49/st FOB rail for Q4 2016 delivery, unchanged from last week. One fuel buyer looking at deals for 2017 noted seeing "some very aggressive" pricing across the entire Appalachian region, with near-term NAPP deals coming in the mid- to upper-$40s/st range.

Get Price >>

difference between nar and gar coal - BINQ Mining

Jan 15, 2013· NON COKING STEAM COAL + COKING COAL, COAL TRADE, INDIA, COAL …. Coal that includes TOTAL MOISTURE, ASH, VOLATILE MATTER, and FIXED CARBON: … CONVERSION FROM GAR TO NAR The difference between net and gross as … »More detailed

Get Price >>

THE COAL MARKET - tradition.com

coal‐producing state in the region, and the second largest coal‐producing state in the United States. Coal mined in the Appalachian coal region is primarily used for steam generation for electricity and metal production and for export. Norfolk, VA is the largest U.S. coal export terminal.

Get Price >>

What Is Coal Preparation? - Energy

What Is Coal Preparation? • Coal preparation is the removal of undesirable material from the Run-of-Mine (ROM) coal by employing separation processes which are able to differentiate between the physical and surface properties of the coal and the impurities. Through coal preparation…

Get Price >>

Convert Btu to kWh - Conversion of Measurement Units

Btu to exawatt-hour Btu to petawatthour Btu to tonne of coal equivalent Btu to centijoule Btu to attojoule Btu to horsepower hour Btu to wattsecond ›› Definition: Btu. The British thermal unit (BTU or Btu) is a non-metric unit of energy, used in the United States and, to a lesser extent, the UK (where it isgenerally only used for heating ...

Get Price >>

Coal Specifications | Ares Asia

Coal Specifications. We exclusively trade thermal coal of Indonesian origin and offer three main calorific values – GAR 4200 kcal/kg, NAR 4700 kcal/kg and NAR 5500 kcal/kg. The table below indicates the typical specifications of each category of coal under the …

Get Price >>

"net BTU" versus "gross BTU" — Heating Help: The Wall

Gene, with steam the boiler does not care so much about the heatloss of the building or the windows or insulation [or the lack thereof] It cares about connected load. The amount of iron connected to the boiler that the steam has to fill. EDR equivalent direct radiation. 240 btu pr sq ft.

Get Price >>

Evaluation of Available Resources of the Pittsburgh (No. 8 ...

performed an estimation of the remaining and available resources of the Pittsburgh (No. 8) coal bed in Ohio. This study represents the first statewide estimation of Pittsburgh coal resources in 14 years. The Pittsburgh (No. 8) coal is the most heavily mined coal bed in Ohio, representing 64 percent of the total coal mined within the state.

Get Price >>

Anthracite - Wikipedia

Anthracite, often referred to as hard coal, is a hard, compact variety of coal that has a submetallic luster.It has the highest carbon content, the fewest impurities, and the highest energy density of all types of coal and is the highest ranking of coals.. Anthracite is the most metamorphosed type of coal (but still represents low-grade metamorphism), in which the carbon content is between 92% ...

Get Price >>

Fuels and Alternate Heat Sources for Commercial Greenhouses

By definition, one Btu equals the amount of energy required to raise a pound of water 1ºF. It takes 8.3 Btu's to raise 1 gallon of water 1ºF. Greenhouse & Floriculture: Fuels and Alternate Heat Sources for Commercial Greenhouses | UMass Center for Agriculture, Food and the Environment

Get Price >>

Price Assessments Catalog | S&P Global Platts

We provide spot and forward price assessments for Oil, Natural Gas, Electric Power, Coal, Petrochemicals, Metals, and Agriculture markets, publishing over 12,000 prices daily. View the latest on our key price assessments across our commodity coverage.

Get Price >>

BTU, Calorie and Joule - Engineering ToolBox

BTU (Btu) - British Thermal Unit - also known as a "heat unit" in United States; Calorie; Joule; BTU - British Thermal Unit. The unit of heat in the imperial system - the BTU - is. the amount of heat required to raise the temperature of one pound of water through 1 o F (58.5 o F - …

Get Price >>

Fuel Cost Calculator - Blaschak Coal

Blaschak Coal Corp. has a network of hundreds of anthracite dealers throughout North America, many of whom will deliver right to your front door. To find the nearest dealer, complete the Contact Form or call us at 570-773-2113 or toll-free at 1-800-553-3117 for more information.

Get Price >>

Standard Grade Coal - Heat Value - Engineering ToolBox

Anthracite Coal is very shiny, hard black coal, high carbon content and energy density, repels moisture, for domestic industrial uses, including smokeless fuel; Bituminous Coal is softer and shiny, moisture content is 8 -20%, possible for coking coals, volatile matter from 16% - 40%, can be used for thermal or metallurgical applications; Sub-bituminous Coal is soft and black with energy ...

Get Price >>

Coal - Wikipedia

A grade between bituminous coal and anthracite was once known as "steam coal" as it was widely used as a fuel for steam locomotives. In this specialized use, it is sometimes known as "sea coal" in the United States. Small "steam coal", also called dry small steam nuts (or DSSN), was used as a fuel for domestic water heating.

Get Price >>

Coal Markets - eia.gov

In the row headings, the Btu values represent heat content per pound of coal, and the SO2 values reflect their percentage of total coal weight. Because the historical spot price data are proprietary, they cannot be released by EIA; see S&P Global.

Get Price >>

USGS Fact Sheet 004-02: Coal Resources of Selected Coal ...

U.S. Geological Survey Fact Sheet 004-02 Online Version 1.0. Coal Resources of Selected Coal Beds and Zones in the Northern and Central Appalachian Basin. By Leslie Ruppert, Susan Tewalt, and Linda Bragg. The Appalachian Basin is one of the most important coal-producing regions in the world (figs. 1-3, table 1).

Get Price >>

How many BTUS in 1 pound of steam - answers.com

Near to 400 pounds. One pound of steam requires the input of 1080 btus of heat added to 32oF water at atmospheric pressure. One ton or 2000 pounds requires the input of 2.16 million btus, and a ...

Get Price >>

kcal/kg to btu/lb Converter, Chart -- EndMemo

Fuel efficiency mass unit conversion between kilocalorie/kilogram and Btu/pound, Btu/pound to kilocalorie/kilogram conversion in batch, kcal/kg Btu/lb conversion chart. ENDMEMO.

Get Price >>

Steam Calculators: Boiler Calculator

[Steam Property Calculator] => Specific Enthalpy = 1,191.0 btu/lbm; Steam Energy Flow = Specific Enthalpy * Mass Flow [ Steam Energy Flow = 92,358 = 1,191.0 btu/lbm * 73.5 klb/hr] Step 2: Determine Feedwater Properties and Mass Flow The feedwater flow rate can be calculated from steam mass flow and blowdown rate:

Get Price >>

Coal Calculations | Mining | SGS

SGS global teams of chemists and experts use a range of coal analytical calculations and indexes to arrive at the calorific values, total hydrogen, Coke Reactivity Index (CRI) and Coke Strength after Reaction (CSR) of your coal sample.

Get Price >>

Steam Calculators: Boiler Calculator

[Steam Property Calculator] => Specific Enthalpy = 1,203.2 btu/lbm; Steam Energy Flow = Specific Enthalpy * Mass Flow [ Steam Energy Flow = 21,199 = 1,203.2 btu/lbm * 16.7 klb/hr] ... Deaerator provides feedwater near the boiling temperature for the deaerator's set operating pressure. (Saturated Liquid) Steam, Boiler, and Blowdown Pressure are ...

Get Price >>